No toxic, no smoke LSZH, irradiated, pur, pvc, rubber, silicone, fep, motors cable.

IEC 60092, no toxic, low smoke, halogen free cable

MA-HK

No toxic, low smoke, halogen free IEC 60092 cable
Description: Conductor insulation of XLPE, sheath SHF1.
Application: Good fire resistance, low smoke emission IEC 61034, low toxicity and acidity index IEC 60754, halogen free, it does not emit halogens in case of fire. Flame resistance: non flame propagating, IEC 60332-1 (test with single vertical cable, flame applied for 60 seconds at 55 mm distance). Conforms to standard IEC 60092-376, “Electrical installation in ships”. Good resistance to common oils and chemical agents.
Max working voltage: 300 V.
Test voltage: 2000 V.

MA-L, IEC 60332-3C, no toxic, low smoke, halogen free cable

MA-LK

No toxic, low smoke, halogen free IEC 60332-3C cable
Description. Conductor insulation of polyolefin, sheath of polyolefin. Non-cross linked materials.
Application. Very good fire resistance, low smoke emission IEC 61034, low toxicity and acidity index IEC 60754, halogen free, it does not emit halogens in case of fire. Flame resistance: non fire propagating, IEC 60332-3C (test with vertical cable bundle, flame applied for 20 minutes at 75 mm distance). Moderate resistance to common oils.
Max working voltage: 300 V.
Test voltage: 2000 V.

IEC 60092, no toxic, low smoke, halogen free shielded cable

MB-HK

No toxic, no smoke, halogen free IEC 60092, shielded cable
Description. Conductor insulation of XLPE, separation soft tape, tinned copper braid, minimum coverage 85%, EMC 89/336/EC. Sheath SHF1.
Application. Good fire resistance, low smoke emission IEC 61034, low toxicity and acidity index IEC 60754, halogen free, it does not emit halogens in case of fire. Flame resistance: non flame propagating, IEC 60332-1 (test with single vertical cable, flame applied for 60 seconds at 55 mm distance). Conforms to standard IEC 60092-376, "Electrical installation in ships". Good resistance to common oils and chemical agents.
Max working voltage: 300 V.
Test voltage: 2000 V.

MB-L, IEC 60332-3C, no toxic, low smoke, halogen free, shielded cable

MB-LK

No toxic, low smoke, halogen free IEC 60332-3C, shielded cable
Description. Conductor insulation of polyolefin, separation soft tape, tinned copper braid, minimum coverage 85%, EMC 89/336/EC. Sheath of polyolefin. Non-cross linked materials.
Application. Very good fire resistance, low smoke emission IEC 61034, low toxicity and acidity  index IEC 60754, halogen free, it does not emit halogens in case of fire. Flame resistance: non fire propagating, IEC 60332-3C (test with vertical cable bundle, flame applied for 20 minutes at 75 mm distance). Moderate resistance to common oils.
Max working voltage: 300 V.
Test voltage: 2000 V.

cross-linked irradiated PUR, welding splatter resistant, halogen free cable

MC-CK

PUR, irradiated, welding splatter resistant cable
Description. Conductor insulation: halogen free polyolefin PP9Y. Sheath of matt halogen free polyether polyurethane (PUR). Cross-linked by irradiation.
Application. The irradiation hardens the sheath outer layer, improving mechanical characteristics and high temperature resistance. Completely halogen free cable, it does not emit halogens in case of fire; flame resistance degree: UL94 horizontal flame test.
Very good resistance to common chemical agents and oils (UL 1581). Good abrasion resistance. Used for automotive and railways industry.
Max working voltage: 300 V.
Test voltage: 2000 V.

PUR, halogen free cable, Li9Y11Y

MC-OE

PUR, halogen free cable
Description. Conductor insulation: halogen free polyolefin PP9Y. Sheath of matt halogen free polyether polyurethane (PUR).
Application. Completely halogen free cable, it does not emit halogens in case of fire; flame resistance degree: UL94 horizontal flame test. Very good resistance to common chemical agents and oils (UL 1581). Abrasion resistance and excellent mobile laying behaviour (7 m/s2, 200 m/min).
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

PUR, halogen free cable, Li9Y11Y

MC-OR

PUR, halogen free cable
Description. Conductor insulation: halogen free polyolefin PP9Y. Sheath of matt halogen free polyether polyurethane (PUR).
Application. Completely halogen free cable, it does not emit halogens in case of fire; flame resistance degree: UL94 horizontal flame test. Very good resistance to common chemical agents and oils (UL 1581). Abrasion resistance and excellent mobile laying behaviour (7 m/s2, 200 m/min).
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

PUR, halogen free cable, Li9Y11Y, UL / CSA

MC-TE

PUR, halogen free, UL 300 V cable
Description. Conductor insulation: halogen free polyolefin PP9Y. Sheath of matt halogen free polyether polyurethane (PUR).
Application. Completely halogen free cable, it does not emit halogens in case of fire; flame resistance degree: UL94 horizontal flame test. Very good resistance to common chemical agents and oils (UL 1581). Abrasion resistance and excellent mobile laying behaviour (7 m/s2, 200 m/min).
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

PUR, polyurethane, UL / CSA 600 V,  IEC 60332-1 cable

MC-UE

PUR, pvc insulation, UL 600 V, IEC 60332-1 cable
Description. Conductor insulation of PVC. Sheath of matt polyether polyurethane (PUR).
Application. Very good cable for industrial applications, only weak points: it contains halogens and has slightly lower performance in mobile laying with respect to the correspondent type of PUR / TPE. Flame resistance degree: UL94 vertical flame test, IEC 60332-1. Very good resistance to common chemical agents and oils (UL 1581). Strong construction. Abrasion resistance and excellent mobile laying behaviour (7 m/s2, 200 m/min), also at low temperature.
Max working voltage: 300 V.
Test voltage: 2000 V.

PUR, halogen free, UL / CSA, shielded, twisted in pair cable

MD-EE

PUR, halogen free, UL 300 V, shielded, twisted in pair cable
Description. Conductor insulation: halogen free polyolefin PP9Y, conductors twisted in pairs, separation soft tape, tinned copper braid, min. coverage 85%, EMC 89/336/EC. Sheath of matt halogen free polyether polyurethane (PUR).
Application. Suitable for reducing crosstalk noises for frequencies up to 500 kHz, see paragraph "Signal Transmission Noises" in the section "Download / Technical Support". Completely halogen free cable, it does not emit halogens in case of fire; flame resistance degree: UL94 horizontal flame test. Very good resistance to common chemical agents and oils (UL 1581). Abrasion resistance and excellent mobile laying behaviour (7m/s2, 200 m/min).
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

PUR, UL / CSA, shielded, halogen free cable

MD-TE

PUR, halogen free, UL 300 V, shielded cable
Description. Conductor insulation of halogen free polyolefin PP9Y, separation soft tape, tinned copper braid, min. coverage 85%, EMC 89/336/EC. Sheath of matt halogen free polyether polyurethane (PUR). Application. Suitable for EMI (Electromagnetic Interferences) noises up to 100 kHz caused by power lines and by inductive circuits such as electrovalves, motors, transformers, etc., see paragraph "Signal Transmission Noises" in the section "Download / Technical Support".
Completely halogen free cable, it does not emit halogens in case of fire; flame resistance degree: UL94 horizontal flame test. Very good resistance to common chemical agents and oils (UL 1581). Abrasion resistance and excellent mobile laying behaviour (7m/s2, 200 m/min).
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

PUR, polyurethane LiYY11Y cable

MF-HE

PUR outer sheath, pvc inside cable
Description. Conductor insulation: special PVC. Internal sheath: special PVC. Outer sheath of matt polyether polyurethane (PUR).
Application. The internal PVC sheath makes for easier cable working with respect to the correspondent types entirely made of PUR. Very good resistance to common chemical agents and oils (UL 1581). Good abrasion resistance. The cables with class 6 conductors have a good behaviour in mobile laying.
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

PUR, polyurethane LiYY11Y cable

MF-HK

PUR outer sheath, pvc inside cable
Description. Conductor insulation: special PVC. Internal sheath: special PVC. Outer sheath of matt polyether polyurethane (PUR).
Application. The internal PVC sheath makes for easier cable working with respect to the correspondent types entirely made of PUR. Very good resistance to common chemical agents and oils (UL 1581). Good abrasion resistance. Class 5 conductors.
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

PUR, ADR polyurethane cable

MF-RK

PUR / PVC, approved ADR cable
Description. Conductor insulation: special PVC. Internal sheath: special PVC. Outer sheath of shiny polyurethane (PUR). TUV approval for ADR specifications.
Application. Designed according to ADR ISO 6722 specification for installations on road vehicles. The internal PVC sheath makes for easier cable working with respect to the correspondent types entirely made of PUR. Good resistance to chemical agents and common oils.
Max working voltage: 50 Vac / 75 Vdc.
Test voltage: 1500 V.

MF-T, PUR, UL / CSA 300 V, polyurethane cable

MF-TE

PUR outer sheath, pvc inside, UL 300 V cable
Description. Conductor insulation: special PVC. Internal sheath: special PVC. Outer sheath of matt polyether polyurethane (PUR).
Application. The internal PVC sheath makes for easier cable working with respect to the corresponding types entirely made of PUR. Very good resistance to common chemical agents and oils (UL 1581). Flame resistance grade: UL94 horizontal flame test. Good abrasion resistance. The cables with class 6 conductors have a good mobile laying behaviour.
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

PUR, UL / CSA 300 V, polyurethane cable

MF-TK

PUR outer sheath, pvc inside, UL 300 V cable
Description. Conductor insulation: special PVC. Internal sheath: special PVC. Outer sheath of matt polyether polyurethane (PUR).
Application. The internal PVC sheath makes for easier cable working with respect to the corresponding types entirely made of PUR. Very good resistance to common chemical agents and oils (UL 1581). Flame resistance grade: UL94 horizontal flame test. Good abrasion resistance. Class 5 conductors.
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

PUR, UL / CSA 300 V, multi-section cable

MH-PF

Multi-section cables, UL 300 V, PUR outer sheath, pvc inside
Description. Conductor insulation: special PVC. Conductors with bigger section for power and earth + reduced section for signals. Internal sheath: special PVC. Outer sheath of matt polyether polyurethane (PUR).
Application. In the distribution boxes, when the common wires carry much more current with respect to the signal wires. The internal PVC sheath makes for easier cable working with respect to the correspondent types entirely made of PUR. Very good resistance to common chemical agents and oils (UL 1581). Good abrasion resistance.
The cables with class 6 conductors have a good behaviour in mobile laying.
Max working voltage: 300 V.
Test voltage: 2000 V.

CEI 20-22 II, IEC 60332-3A, PVC, multi-section cable

MH-PN

Multi-section cable, CEI 20-22 II, PVC
Description. Conductor insulation: special PVC. Conductors with bigger section for power and earth + reduced section for signals. Outer sheath: special PVC.
Application. In the distribution boxes, when the common wires carry much more current with respect to the signal wires. Moderate resistance to common oils (UL 1581). Flame resistance grade: CEI 20-22 II and IEC 60332-3A. Class 5 conductors. Limited resistance to abrasion.
Max working voltage: 300 V.
Test voltage: 2000 V.

PUR, Can Open shielded twisted pair cable

ML-CD

Can Open, UL, PUR cable
Description. Conductor insulation: polyolefin. Wires twisted in pairs. Tinned copper braid, min. coverage 85%, EMC 89/336/EC. Sheath of matt polyether polyurethane (PUR).
Application. Designed according to Can Open specification. Very good resistance to common chemical agents and oils (UL1581). Abrasion resistance and excellent mobile laying behaviour (7 m/s2, 180 m/min).
Max working voltage: 250 V spike voltage.
Test voltage: 1500 V.

PVC, Can Open shielded twisted pair cable

ML-CP

Can Open, UL, PVC cable
Description. Conductor insulation: polyolefin. Wires twisted in pair. Tinned copper braid, min. coverage 85%, EMC 89/336/EC. Sheath of special PVC.
Application. Designed according to Can Open specification. Good resistance to common oils(UL1581).
Max working voltage: 250 V spike voltage.
Test voltage: 1500 V.

PUR, DeviceNet shielded twisted pair cable

ML-DD

DeviceNet, UL, PUR cable
Description. Conductor insulation: signal, foam skin; power, PE. Shielded pairs with aluminium/polyester tape. Tinned copper braid on total, min. coverage 70%, EMC 89/336/EC. Sheath of matt polyether polyurethane (PUR).
Application. Designed according to DeviceNet specification. Very good resistance to common chemical agents and oils (UL1581). Abrasion resistance and excellent mobile laying behaviour (7 m/s2, 180 m/min).
Max working voltage: 250 V spike voltage.
Test voltage: 1500 V.

PVC, DeviceNet shielded twisted pair cable

ML-DP

DeviceNet, UL, PVC cable
Description. Conductor insulation: signal, foam skin; power, special PVC. Shielded pairs with aluminium/polyester tape. Tinned copper braid on total, min. coverage 70%, EMC 89/336/EC. Sheath of special PVC.
Application. Designed according to DeviceNet specification. Good resistance to common oils UL1581).
Max working voltage: 250 V spike voltage.
Test voltage: 1500 V.

PUR, Profibus shielded cable

ML-RD

Profibus, UL, PUR cable
Description. Conductor insulation: signal, foam skin; power, Polypropylene. Shielded pairs with aluminium/polyester tape. Tinned copper braid on total signal, min. coverage 65%, EMC 89/336/EC. Sheath of matt polyether polyurethane (PUR).
Application. Designed according to Profibus specification. Very good resistance to common chemical agents and oils (UL1581). Abrasion resistance and excellent mobile laying behaviour (7 m/s2, 180 m/min).
Max working voltage: 250 V spike voltage.
Test voltage: 1500 V.

PVC, Profibus shielded cable

ML-RP

Profibus, UL, PVC cable
Description. Conductor insulation: signal, foam skin; power, special PVC. Shielded pairs with aluminium/polyester tape. Tinned copper braid on total signal, min. coverage 65%, EMC 89/336/EC. Sheath of special PVC.
Application. Designed according to Profibus specification. Good resistance to common oils (UL1581).
Max working voltage: 250 V spike voltage.
Test voltage: 1500 V.

PVC 90 C degree, 60332-3A, LiYY cable

MN-AE

PVC, 90 C degree, CEI 20-22 II cable
Description. Conductor insulation: special PVC. Outer sheath: special PVC.
Application. Suitable for connections in industrial automation. Moderate resistance to common oils. Flame resistance grade: CEI 20-22 II and IEC 60332-3A. The cables with class 6 conductors have a good behaviour in mobile laying. Limited resistance to abrasion.
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

PVC 70 C degree, 60332-3A, LiYY cable

MN-BK

PVC, 70 C degree, CEI 20-22 II cable
Description. Conductor insulation: special PVC. Outer sheath: special PVC.
Application. Suitable for connections in industrial automation. Moderate resistance to common oils. Flame resistance grade: CEI 20-22 II and IEC 60332-3A. Limited resistance to abrasion.
Class 5 conductors.
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

PVC 105 C degree, LiYYW cable

MN-FK

PVC cable, 105 C degree
Description. Conductor insulation: special PVC. Outer sheath: special PVC.
Application. Suitable for connections in industrial automation where for long periods a heat and cold resistant and soft cable is required.
Moderate resistance to common oils. Flame resistance grade: self-extinguishing. Limited resistance to abrasion. Class 5 conductors.
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

PVC 90 C degree, LiYY cable

MN-GE

PVC cable, 90 C degree
Description. Conductor insulation: special PVC. Outer sheath: special PVC.
Application. Suitable for connections in industrial automation where for long periods a heat and cold resistant and soft cable is required. Moderate resistance to common oils. Flame resistance grade: self-extinguishing. The cables with class 6 conductors have a good behaviour in mobile laying. Limited resistance to abrasion.
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

PVC 90 C degree, LiYY cable

MN-GK

PVC cable, 90 C degree
Description. Conductor insulation: special PVC. Outer sheath: special PVC.
Application. Suitable for connections in industrial automation where for long periods a heat and cold resistant and soft cable is required.
Moderate resistance to common oils. Flame resistance grade: self-extinguishing. Class 5 conductors. Limited resistance to abrasion.
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

PVC 70 C degree, LiYY cable

MN-HK

PVC cable, 70 C degree
Description. Conductor insulation: PVC. Outer sheath: PVC.
Application. Suitable for connections in industrial automation.
Moderate resistance to common oils. Flame resistance grade: self-extinguishing. Limited resistance to abrasion. Class 5 conductors.
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

intrinsically safe, IEC 60332-3A, PVC 70 C degree, LiYY cable

MN-NE

PVC cable, intrinsically safe apparatus
Description. Conductor insulation: special PVC. Outer sheath: special PVC.
Application. Cables used in explosion risk area "i" (IEC 60079-11 Intrinsically Safe) are blue coloured to be always easily identified. Moderate resistance to common oils. Flame resistance grade: CEI 20-22 II and IEC 60332-3A. Limited resistance to abrasion. Cables for intrinsically safe areas are also available in a shielded version: see MP-NK.
Class 6 conductors.
Mutual Capacitance: wire / wire about 110 nF / km @ 1 kHz.
Inductance: about 0,65 mH / km.
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

intrinsically safe, IEC 60332-3A, PVC 70 C degree, LiYY cable

MN-NK

PVC, intrinsically safe apparatus cable
Description. Conductor insulation: special PVC. Outer sheath: special PVC.
Application. Cables used in explosion risk area "i" (IEC 60079-11 Intrinsically Safe) are blue coloured to be always easily identified. Moderate resistance to common oils. Flame resistance grade: CEI 20-22 II and IEC 60332-3A. Limited resistance to abrasion. Cables for intrinsically safe areas are also available in a shielded version: see MP-NK.
Class 5 conductors. 
Mutual Capacitance: wire / wire about 110 nF / km @ 1 kHz.
Inductance: about 0,65 mH / km.
Max working voltage: 300 V.
Test voltage: 1500V up to 0,25 mm2, 2000 V over.

CEI 20-22 II, IEMMEQU FROR approved, PVC cable

MN-PK7

PVC, IEMMEQU FROR CEI 20-22 II approved cable
Description. Conductor insulation: PVC. Outer sheath: PVC.
Application. Suitable for connections of portable appliances, where the cable can be frequently moved and risk to be crushed. Moderate resistance to common oils. IEMMEQU approved series according to CEI 20-22 II (IEC 60332-3A). Limited resistance to abrasion.
Max working voltage: 300/500 V and 450/750 V.
Test voltage: 2000 V and 2500 V according to norms.

PVC, HAR (European Harmonization) approved VV-F cable

MN-PK9

PVC, HAR approved cable
Description. Conductor insulation: PVC. Outer sheath: PVC.
Application. Suitable for connections of portable appliances, where the cable can be frequently moved and risk to be crushed. Moderate resistance to common oils. HAR (European Harmonization) approved series. Limited resistance to abrasion.
Max working voltage: 300/500 V and 450/750 V.
Test voltage: 2000 V and 2500 V according to norms.

PVC, UL PLTC approved cable

MN-ST

PVC cable, UL 300 V, PLTC type
Description. Conductor insulation: special PVC. Outer sheath: special PVC.
Application. PLTC series is approved "Direct Burial" and "Sunlight Resistant" as well, it can be used for home, industrial installation, directly buried outdoor or in internal floor without using conduits, according to UL and CSA directives. Class 5 conductors. Limited resistance to abrasion. Good resistance to common oils (UL 1581). Good flame resistance (UL 1581).
Max working voltage: 300 V.
Test voltage: 2000 V.

PVC, UL SVT approved cable

MN-SV

PVC cable, UL 300 V, SVT type
Description. Conductor insulation: special PVC. Outer sheath: special PVC.
Application. SVT series has been designed for connections of portable appliances, where the cable can be frequently moved and risk to be crushed. Class 5 conductors. Limited resistance to abrasion. Good resistance to common oils (UL 1581). Good flame resistance (UL 1581).
Max working voltage: 300 V.
Test voltage: 2000 V.

PVC, CSA / UL style 2464 approved cable

MN-TE

PVC cable, UL 300 V, style 2464
Description. Conductor insulation: special PVC. Outer sheath: special PVC.
Application. Style 2464 is suitable for generic applications on industrial machinery. The cables with class 6 conductors have a good behaviour in mobile laying. Limited resistance to abrasion. Good resistance to common oils (UL 1581). Good flame resistance (UL 1581).
Max working voltage: 300 V.
Test voltage: 2000 V.

PVC, CSA / UL style 2464 approved cable

MN-TK

PVC cable, UL 300 V, style 2464
Description. Conductor insulation: special PVC. Outer sheath: special PVC.
Application. Style 2464 is suitable for generic applications on industrial machinery. Class 5 conductors. Limited resistance to abrasion. Good resistance to common oils (UL 1581). Good flame resistance (UL 1581).
Max working voltage: 300 V.
Test voltage: 2000 V.

PVC cable, cold resistant - 40 C degree, UL approved

MN-TM

PVC cable, UL 300 V, cold resistant (- 40 C degree)
Description. Conductor insulation: special PVC. Outer sheath: special PVC.
Application. This style is suitable for generic applications on industrial machinery. This cable materials and dimensions make it suitable to be used with low temperature. Class 5 conductors. Limited resistance to abrasion. Good resistance to common oils (UL 1581). Flame resistance degree: UL94 vertical flame test, IEC 60332-1.
Max working voltage: 300 V.
Test voltage: 2000 V.

PVC, HAR-UL-CSA tri-norm, multi-norm, 600 V approved cable

MN-UK

PVC cable, HAR-UL-CSA tri-norm, 600 V
Description. Conductor insulation: special PVC. Outer sheath: special PVC.
Application. This cable is particularly useful for industrial automation; it is approved for three big markets: Europe, Canada and USA. Limited resistance to abrasion. Good resistance to common oils (UL 1581). Flame resistance degree: UL94 vertical flame test, IEC 60332-1. Class 5 conductors.
Max working voltage: 600 V.
Test voltage: 2500 V.

PVC LiYCY shielded cable, IEC 60332-3A, CEI 20-22 II

MP-BK

PVC, CEI 20-22 II shielded cable
Description. Conductor insulation: special PVC, separation soft tape, tinned copper braid, min. coverage 85%, EMC 89/336/EC. Outer sheath: special PVC.
Application. Suitable for industrial application connection. It reduces EMI (Electromagnetic Interferences) noises up to 100 kHz caused by power lines and by inductive circuits such as electrovalves, motors, transformers, etc. , see paragraph "Signal Transmission Noises" in the section "Download / Technical Support". Moderate resistance to common oils. Flame resistance degree: CEI 20-22 II and IEC 60332-3A. Limited resistance to abrasion. Class 5 conductors.
Max working voltage: 300 V.
Test voltage: 1500 V up to 0,25 mm2, 2000 V over.

PVC, intrinsically safe, IEC 60332-3A, LiYCY shielded cable

MP-NK

PVC, intrinsically safe apparatus, shielded cable
Description. Conductor insulation: special PVC, separation soft tape, tinned copper braid, min. coverage 85%, EMC 89/336/EC. Outer sheath: special PVC.
Application. Cables used in explosion risk area "i" (IEC 60079-11 Intrinsically Safe) are blue coloured to be always easily identified. This screen reduces EMI (Electromagnetic Interferences) noises up to 100 kHz caused by power lines and by inductive circuits such as electrovalves, motors, transformers, etc. , see paragraph "Signal Transmission Noises" in the section "Download / Technical Support". Moderate resistance to common oils. Flame resistance grade: CEI 20-22 II and IEC 60332-3A. Limited resistance to abrasion. Cables for intrinsically safe areas are also available in a non shielded version: see MN-NK. Class 5 conductors.
Mutual Capacitance: wire / wire about 130 nF/km @ 1 kHz; wire / shielding about 185 nF/km.
Inductance: about 0,65 mH / km.
Max working voltage: 300 V.
Test voltage: 1500V up to 0,25 mm2, 2000 V over.

PVC UL / CSA 300V approved shielded cable

MP-TE

PVC, UL 300 V, shielded cable
Description. Conductor insulation: special PVC, separation soft tape, tinned copper braid, min. coverage 85%, EMC 89/336/EC. Outer sheath: special PVC.
Application. Suitable for industrial application connection. It reduces EMI (Electromagnetic Interferences) noises up to 100 kHz caused by power lines and by inductive circuits such as electrovalves, motors, transformers, etc. , see paragraph "Signal Transmission Noises" in the section "Download / Technical Support". The cables with class 6 conductors have a good behaviour in mobile laying. Good resistance to common oils (UL 1581). Good flame resistance: (UL 1581). Limited resistance to abrasion.
Max working voltage: 300 V.
Test voltage: 2000 V.

PVC UL / CSA 300V approved shielded cable

MP-TK

PVC, UL 300 V, shielded cable
Description. Conductor insulation: special PVC, separation soft tape, tinned copper braid, min. coverage 85%, EMC 89/336/EC. Outer sheath: special PVC.
Application. Suitable for industrial application connection. It reduces EMI (Electromagnetic Interferences) noises up to 100 kHz caused by power lines and by inductive circuits such as electrovalves, motors, transformers, etc. , see paragraph "Signal Transmission Noises" in the section "Download / Technical Support". Class 5 conductors. Good resistance to common oils (UL 1581). Good flame resistance: (UL 1581). Limited resistance to abrasion.
Max working voltage: 300 V.
Test voltage: 2000 V.

rubber HAR RN-F approved cable

MR-PK

Rubber sheath, rubber insulation, RN-F series, HAR approved cable
Description. Conductor insulation: EI4 rubber. Outer sheath: EM2 rubber.
Application. Suitable for wet and dry environments, permanent outdoor and indoor use. Approved with HAR mark (European Harmonization). Flame resistance degree: IEC 60332-1. Good resistance to oils, water and weather. Good resistance to abrasion.
Max working voltage: 300/500 V up to 1,00 mm2 and 450/750 V over.
Test voltage: 2000 V up to 1,00 mm2 and 2500 V over, according to norms.

PUR-rubber HAR BQ-F approved cable

MR-QK

PUR cable, rubber insulation, BQ-F series, HAR approved, cold resistant (- 40 C degree)
Description. Conductor insulation: EI6 rubber. Sheath of matt halogen free polyether polyurethane (PUR).
Application. Suitable for wet and dry environments, permanent indoor and outdoor use even at very low temperature. Approved with HAR mark (European Harmonization). Flame resistance degree: IEC 60332-1. Good resistance to oils, water and weather. Good resistance to abrasion, tearing and cutting. Good flexibility at low temperature down to -40°C.
Max working voltage: 300/500 V up to 1,00 mm2 and 450/750 V.
Test voltage: 2000 V up to 1,00 mm2 and 2500 V over, according to norms.

high and low temperature silicone cable

MS-GK

Silicone cable, high and low temperature
Description. Conductor insulation: silicone. Outer sheath: silicone.
Application. Very good behaviour at high and low temperatures. Completely halogen free cable, it does not emit halogens in case of fire; flame resistance degree: IEC 60332-1. Moderate resistance to common oils. Good resistance to wet application and weather. Low resistance to abrasion. Not to be used in continuous mobile application.
Max working voltage: 300/500 V.
Test voltage: 2000 V.

high and low temperature, chemical agents resistant FEP cable

MS-MK

FEP cable, high and low temperature and chemical agents resistant
Description. Tinned copper conductors. Insulation: FEP (Fluorethylene-propylene). Sheath of FEP (Fluorethylene-propylene).
Application. Employed in the industry in critical cabling because it maintains its characteristics practically unchanged even with almost all chemical substances in a temperature range between -80 C degree and +200 °C. Flame resistance degree: non flame propagating. Good abrasion resistance.
Max working voltage: 600 V.
Test voltage: 2500 V.

high and low temperature, chemical agents resistant shielded FEP cable

MS-PK

FEP cable, high and low temperature and chemical agents resistant, shielded
Description. Tinned copper conductors. Insulation: FEP (Fluorethylene-propylene). Tinned copper braid, min. coverage 85%, EMC 89/336/EC. Sheath of FEP (Fluorethylene-propylene).
Application. Employed in the industry in critical cabling because it maintains its characteristics practically unchanged even with almost all chemical substances in a temperature range between -80 C degree and +200 °C. Flame resistance degree: non flame propagating. Good abrasion resistance.
Max working voltage: 600 V.
Test voltage: 2500 V.

Brushless motor cable, shielded PUR

MV-ED

Brushless motor cables PUR
Description. Conductor insulation of halogen free TPE-E, separation soft tape, tinned copper braid, minimum coverage 85%, EMC 89/336/EC. Sheath of matt halogen free polyether polyurethane (PUR).
Application. Designed for brushless motors for heavy duty applications. Completely halogen free cable, it does not emit halogens in case of fire. Flame resistance degree: UL94 horizontal flame test, IEC 60332-1. Very good resistance to common chemical agents and oils (UL 1581). Abrasion resistance and excellent mobile laying behaviour (10 m/s2, 220 m/min).
Max working voltage: 600/1000 V.
Test voltage: 4000 V.

Brushless motor cable, shielded PVC

MV-EP

Brushless motor cables PVC
Description. Conductor insulation: special PVC, separation soft tape, tinned copper braid, min. coverage 85%, EMC 89/336/EC. Outer sheath: special PVC.
Application. Designed for brushless motors for applications less heavy duty with respect to the correspondent polyurethane types. Flame resistance degree: UL94 horizontal flame test, IEC60332-1. Good resistance to common oils (UL 1581). Very good mobile laying behaviour (6 m/s2, 160 m/min). Limited resistance to abrasion.
Max working voltage: 600/1000 V.
Test voltage: 4000 V.

Siemens style brushless motor cable, shielded PUR

MV-LD

Siemens ® brushless motor cables PUR
Description. Conductor insulation of halogen free TPE-E, separation soft tape, tinned copper braid, min. coverage 85%, on the signal pair and on the total, EMC 89/336/EC. Sheath of matt halogen free polyether polyurethane (PUR).
Application. Designed for brushless motors for heavy duty applications. Completely halogen free cable, it does not emit halogens in case of fire. Flame resistance degree: UL94 horizontal flame test, IEC 60332-1. Very good resistance to common chemical agents and oils (UL 1581). Abrasion resistance and excellent mobile laying behaviour (10 m/s2, 220 m/min).
Max working voltage: power 600/1000 V, signal 250V.
Test voltage: power 4000 V, signal 2000 V.

Siemens style brushless motor cable, shielded PVC

MV-LP

Siemens ® brushless motor cables PVC
Description. Conductor insulation: special PVC, separation soft tape, tinned copper braid, min. coverage 85%, on the signal pair and on the total, EMC 89/336/EC. Outer sheath: special PVC.
Application. Designed for brushless motors for applications less heavy duty with respect to the correspondent polyurethane types. Flame resistance degree: UL94 horizontal flame test, IEC60332-1. Good resistance to common oils (UL 1581). Very good mobile laying behaviour (6 m/s2, 160 m/min). Limited resistance to abrasion.
Max working voltage: power 600/1000 V, signal 250V.
Test voltage: power 4000 V, signal 2000 V.

Indramat style brushless motor cable, shielded PUR

MV-MD

Indramat ® brushless motor cables PUR
Description. Conductor insulation of halogen free TPE-E, separation soft tape, tinned copper braid, min. coverage 85%, on each signal pair and on the total, EMC 89/336/EC. Sheath of matt halogen free polyether polyurethane (PUR).
Application. Designed for brushless motors for heavy duty applications. Completely halogen free cable, it does not emit halogens in case of fire. Flame resistance degree: UL94 horizontal flame test, IEC 60332-1. Very good resistance to common chemical agents and oils (UL 1581). Abrasion resistance and excellent mobile laying behaviour (10 m/s2, 220 m/min).
Max working voltage: 1000 V.
Test voltage: 4000 V.

shielded pairs control cable, PUR

MV-PD

Control connection cables PUR
Description. Conductor insulation, separation soft tape, tinned copper braid, min. coverage 85%. The shielding on the internal pairs, where it is present, is a bare copper spiral, so that it is guaranteed the maximum flexibility, EMC 89/336/EC. Sheath of matt polyether polyurethane (PUR).
Application. Handling and measurement systems, numeric control machines, etc. Reliable data transmission and excellent compliance according to EMC requirements. Very good resistance to common chemical agents and oils (UL 1581). Abrasion resistance and excellent mobile laying behaviour (10 m/s2, 220 m/min).
Max working voltage: 250 V.
Test voltage: 1500 V.

shielded single pairs resolver cable, PUR

MV-SD

Resolver cables, single pairs shielding, PUR
Description. Conductor insulation of PP, separation soft tape, tinned copper braid, min. coverage 85% and PVC sheath over each signal pair, EMC 89/336/EC. Sheath of matt halogen free polyether polyurethane (PUR).
Application. Designed for Resolver connection in particularly heavy duty applications. Very good resistance to common chemical agents and oils (UL 1581). Abrasion resistance and excellent mobile laying behaviour (10 m/s2, 220 m/min). Not for torsional stress.
Max working voltage: 250 V.
Test voltage: 1500 V.

total and single pairs shielded resolver cable, PUR

MV-SF

Resolver cables, total and single pairs shielding, PUR
Description. Conductor insulation of PP, separation soft tape, tinned copper braid, minimum coverage 85% and PVC sheath over each signal pair. Shielding on the total EMC 89/336/EC. Overall sheath of matt halogen free polyether polyurethane (PUR).
Application. Designed for Resolver connection in particularly heavy duty applications. Very good resistance to common chemical agents and oils (UL 1581). Abrasion resistance and excellent mobile laying behaviour (10 m/s2, 220 m/min).
Max working voltage: 250 V.
Test voltage: 1500 V.